These panels generally come with a painted mill finish or a clear acrylic finish.
Low slope roof section.
Vertical end laps should be at least 3 inches and horizontal laps 6 inches.
The reason water ponds on a low slope roof is a possible misinterpretation of the 1 4 in 12 minimum slope by the building code.
Roof coverings installed on low slope roofs roof slope 2 12 in accordance with section 1507 shall resist impact damage based on the results of tests conducted in accordance with astm d3746 astm d4272 cgsb 37 gp 52m or the resistance to foot traffic test in section 5 5 of fm 4470.
For anything less than that you should use a roofing material specifically made for low slope roofs.
Low slope roofs present special challenges in terms of preventing unique types of damage.
Then apply standard asphalt shingles over the membrane.
Regular asphalt shingles and standard skylights will work at pitches of 4 12 or greater but at lower pitches you have to use different materials.
For a low slope residential roof there are two main options.
1 3 5 design pressure coefficients for roof zones wind produces different magnitudes of pressure acting on the surfaces of a building due to the building s geometry and can create small areas of higher pressure on a surface while at the same time other areas on the same surface experience lower pressures.
Some building codes allow as low as a 2 slope with asphalt shingles if additional steps are taken.
A 3 per foot slope is considered low but may be acceptable if a double layer of felt is used.
In areas with extensive snowfall or windblown rain the best protection against leakage is to cover the entire low slope roof area with a bituminous membrane as shown in figure 2 4.
The usual slope for asphalt shingles is a 4 or greater rise for every horizontal foot of run.
Roof fast 95 base iko roof fast 95 base is a self adhesive product that can easily be cold applied on low slope roofs.
Low slope structural roofing generally used on roof pitches ranging from 12 to 3 12 consists of interlocking panels commonly called standing seam roofing that run vertically along the roof surface.
By low slope roofing we mean any roof that is pitched at less than 4 inches of rise in 12 inches of run or 4 12 pitch.
For buildings with low slope roofs less than 2 12 slope the wind speed at eave height is used.
1 cover the entire surface with a self adhesive flashing membrane such as grace ice water shield there are many equivalent products.
That includes soldered metal roofing or synthetic membranes.
The only function the three tab shingles perform at that low a slope is decorative that s a legitimate use of shingles when you wish to preserve a consistent appearance but they do not function as a weather barrier in such installations that function is being performed it s being performed at all by the underlayment and or flashing below the shingles which in this case must be a material with self sealing properties to prevent water intrusion at the shingle s fasteners.