There are some opinions that standing seam metal roof minimum slope is 12 but it increases the possibility of leaking on the few first days of snow arrival.
Low slope roof underlayment for standing seam roof.
Metal panel roof system description there is only one category of metal roof systems used in low slope applications structural metal panel.
Their fasteners are either concealed or screwed at the top of a ridge which makes them less likely to leak.
But the taller profiles like standing seam and pbr shown below can be installed on roofs with as low as 1 4 or 1 2 in 12 pitch.
Lower slopes for low slope standing seam metal roof applications strictly peel and stick underlayment is a better choice.
Clay or cement tiles can be used on a wide range of roof pitches.
In country with heavy snow and tough winter days the metal roof minimum slope is recommended to be 1 12.
On low slope roofs like you have a water proof membrane like i ws is good insurance.
Once the high temperature ice and water shield has been laid down you can now add the second underlayment layer.
Low slope metal roofs require less material which reduces the overall load on the building s structure.
Asphalt saturated felt along the eaves and lap succeeding courses by 19 inches as shown in figure 2 3.
Guide to roofing underlayment installation on low slope roofs with asphalt shingles asphalt shingles can be used on roofs with a slope of 2 12 to 4 12 if double coverage underlayment is used.
For pitches of 2 5 12 up to 4 12 the roof requires double underlayment.
Low slope roofs are not totally flat their roof slope generally ranges from 1 4 12 to 3 12.
Low slope metal roofs have simple geometries and are easier and less expensive to install that medium to steep slope roofs.
I don t see any point in sealing the roof penetrations to the sheathing.
These advantages and disadvantages do not apply to granulated synthetic underlayment as it is not to be used directly under metal roofing.
Underlayment is important for a metal roof you get night time condensation on the underside of the panels you don t want that to get into your deck.
Slopes above 19 12 are not recommended since tiles on very steep roofs can rattle.
Structural metal panel roof systems can be used for low slope roofs because of their hydrostatic or water barrier characteristics.
Peel and stick is only needed for low slope or if your roof has a issues with ice dams 4a doesn t sound like a climate for that.
If the roof slope is below 3 12 pitch see our previous post on how to determine a roof s pitch the entire roof should be covered but only if the roof is conventionally vented cold roof construction.